Effect Of Different Irrigation Materials on Cyclic Fatigue Resistance of Nickel Titanium Rotary Files: An In-Vitro Study
DOI:
https://doi.org/10.23918/eajse.v9i3p07Keywords:
Cyclic Fatigue, Endodontics, NiTi, Irrigation Solutions, Sodium Hypochlorite, EDTA, Fracture ResistanceAbstract
With the advancements been made in Nickel Titanium (NiTi) rotary files to decrease complications during root canal treatment, however, different irrigation solutions are being used during the procedure that might affect the cyclic fatigue resistance of instruments. In this study effect of irrigation solutions on NiTi was compared.
A total of 30 files were divided into three groups of sodium hypochlorite, EDTA and normal saline, each group containing 10 files. After the immersion the files were rotated inside a custom-made block until the files were fractured.
According to t-test group II (EDTA) showed maximum mean time taken until fracture and least mean time in case of Group I (sodium). however according to ANOVA test no significant difference between the experimental groups were found.
Within the limitations of this study, EDTA had the least effect while sodium had the greatest effect on cyclic fatigue of the instruments.
References
[1] Fu M, Zhang Z, Hou B. Removal of broken files from root canals by using ultrasonic
techniques combined with dental microscope: a retrospective analysis of treatment outcome. J
Endod. 2011 May; 37(5): 619–22. https://doi.org/10.1016/j.joen.2011.02.016
[2] Pedullà E, Lo Savio F, La Rosa GRM, Miccoli G, Bruno E, Rapisarda S, et al. Cyclic fatigue
resistance, torsional resistance, and metallurgical characteristics of M3 Rotary and M3 Pro
Gold NiTi files. Restor Dent Endod. 2018 May; 43(2): e25.
https://doi.org/10.5395/rde.2018.43
[3] Faraj BOH, Salman RF. Root Dentine Strain Generation during Root Canal Instrumentation
with Rotation and Reciprocation Motions. Polytech J. 2020 Dec 30; 10(2): 66–70.
https://doi.org/10.25156/ptj.v10n2y2020.pp66-70
[4] Elnaghy AM. Cyclic fatigue resistance of ProTaper Next nickel-titanium rotary files. Int Endod
J. 2014 Nov; 47(11): 1034–9. https://doi.org/10.1111/iej.12244
[5] Yared GM, Dagher FEB, Machtou P, Kulkarni GK. Influence of rotational speed, torque and
operator proficiency on failure of Greater Taper files. Int Endod J. 2002 Jan; 35(1): 7–12.
https://doi.org/10.1046/j.1365-2591.2002.00443
[6] Chaves Craveiro de Melo M, Guiomar de Azevedo Bahia M, Lopes Buono VT. Fatigue
resistance of engine-driven rotary nickel-titanium endodontic instruments. J Endod. 2002 Nov;
28(11): 765–9. https://doi.org/10.1097/00004770-200211000-00005
[7] Alfawaz H, Alqedairi A, Alhamdan M, Alkhzim N, Alfarraj S, Jamleh A. Effect of NaOCl and
EDTA irrigating solutions on the cyclic fatigue resistance of EdgeTaper Platinum instruments.
BMC Oral Health. 2022 May 22; 22(1): 195. https://doi.org/10.1186/s12903-022-02215-0
[8] Shen Y, Haapasalo M. Three-dimensional analysis of cutting behavior of nickel-titanium rotary
instruments by microcomputed tomography. J Endod. 2008 May; 34(5): 606–10.
https://doi.org/10.1016/j.joen.2008.02.025
[9] Elbahary S, Haj-yahya S, Khawalid M, Tsesis I, Rosen E, Habashi W, et al. Effects of different
irrigation protocols on dentin surfaces as revealed through quantitative 3D surface texture
analysis. Sci Rep. 2020 Dec 16; 10(1): 22073. https://doi.org/10.1038/s41598-020-79003-9
[10] Ali A, Bhosale A, Pawar S, Kakti A, Bichpuriya A, Agwan MA. Current Trends in Root Canal
Irrigation. Cureus. 2022 May; 14(5): e24833. https://doi.org/10.7759/cureus.24833
[11] Torabinejad M, Handysides R, Khademi AA, Bakland LK. Clinical implications of the smear
layer in endodontics: a review. Oral Surg Oral Med Oral Pathol Oral Radiol Endod. 2002 Dec;
94(6): 658–66. https://doi.org/10.1067/moe.2002.128962
[12] Choi J, Oh S, Kim YC, Jee KK, Kum K, Chang S. Fracture Resistance of K3 Nickel-Titanium
Files Made from Different Thermal Treatments. Bioinorg Chem Appl. 2016; 2016: 6374721.
https://doi.org/10.1155/2016/6374721
[13] Tabassum S, Zafar K, Umer F. Nickel-Titanium Rotary File Systems: What’s New? Eur Endod
J. 2019 Oct 18; 4(3): 111–7. https://doi.org/10.14744%2Feej.2019.80664
[14] Chandler N, Chellappa D. Lubrication during root canal treatment. Aust Endod J. 2019; 45(1):
106–10. https://doi.org/10.1111/aej.12282
[15] Dagna A, Poggio C, Beltrami R, Chiesa M, Bianchi S. Cyclic Fatigue Resistance of Three Niti
Single-File Systems after Immersion in EDTA. Dentistry. 2014 Jan 1; 4: 184.
http://dx.doi.org/10.4172/2161-1122.1000184
[16] Boessler C, Peters OA, Zehnder M. Impact of lubricant parameters on rotary instrument torque
and force. J Endod. 2007 Mar; 33(3): 280–3. https://doi.org/10.1016/j.joen.2006.11.007
[17] Erik CE, Özyürek T. Effects of etidronate, NaOCl, EDTA irrigation solutions and their
combinations on cyclic fatigue resistance of nickel-titanium single-file rotary and reciprocating
instruments at body temperature. Odontology. 2019 Apr; 107(2): 190–5.
https://doi.org/10.1007/s10266-018-0388-8
[18] Cai JJ, Tang XN, Ge JY. Effect of irrigation on surface roughness and fatigue resistance of
controlled memory wire nickel-titanium instruments. Int Endod J. 2017 Jul; 50(7): 718–24.
Downloads
Published
Issue
Section
License
LicenseEurasian J. Sci. Eng is distributed under the terms of the Creative Commons Attribution License 4.0 (CC BY-4.0) https://creativecommons.org/licenses/by/4.0/