Comparison Of Fracture Torque And Level Of Fracture Of Two Orthodontic Mini-Screw ( AN IN VITRO STUDY)

Authors

DOI:

https://doi.org/10.23918/eajse.v9i2p19

Keywords:

Mini Screws, Anchorage, GNI Mini Screws, Tomas Mini Screws

Abstract

Certain malocclusions may benefit from the use of mini-screw anchoring control during orthodontic treatment. In contrast, the failure of little screws will have a substantial influence on treatment efficiency and effectiveness. Twenty orthodontic mini-implants of (Tomas. Dentaurm. Germany; GNI, Korean) were inspected in an in-vitro study. A digital torque gauge was positioned perpendicular to the bone surface and placed into the 10 mm thick bovine femoral cortical bone in the same manner as mini-implants. The insertion  done through the hand driver simulations of insertion intraorally. The Tomas offered a high fracture torque value compared with GNI. GNI gave a high percentage of fracture at an apical level while Tomas gave at the middle of it.

References

[1] Nanda R, Uribe FA, Yadav S. Temporary anchorage devices in orthodontics e-book: Elsevier Health Sciences. 2019.

[2] Umalkar SS, Jadhav VV, Paul P, Reche A, Jadhav Sr VV. Modern Anchorage Systems in Orthodontics. Cureus. 2022; 14(11). https://doi.org/10.7759/cureus.31476

[3] Mizrahi E, Mizrahi B. Mini-screw implants (temporary anchorage devices): orthodontic and pre-prosthetic applications. Journal of Orthodontics. 2007; 34(2): 80-94. https://doi.org/10.1179/146531207225021987

[4] Cope JB, editor Temporary anchorage devices in orthodontics: a paradigm shift. Seminars in orthodontics. 2005; Elsevier. https://doi.org/10.1053/j.sodo.2004.11.002

[5] Tsichlaki A, Chin SY, Pandis N, Fleming PS. How long does treatment with fixed orthodontic appliances last? A systematic review. American journal of orthodontics and dentofacial orthopedics. 2016; 149(3): 308-18. https://doi.org/10.1016/j.ajodo.2015.09.020

[6] O'Brien K. Lets talk about micro-osteoperforation…. Trials. 2017.

[7] Cheung T, Park J, Lee D, Kim C, Olson J, Javadi S, et al. Ability of mini-implant–facilitated micro-osteoperforations to accelerate tooth movement in rats. American Journal of Orthodontics and Dentofacial Orthopedics. 2016; 150(6): 958-67. https://doi.org/10.1016/j.ajodo.2016.04.030

[8] Nimeri G, Kau CH, Abou-Kheir NS, Corona R. Acceleration of tooth movement during orthodontic treatment-a frontier in orthodontics. Progress in orthodontics. 2013; 14(1): 1-8. https://doi.org/10.1186/2196-1042-14-42

[9] Wilmes B, Rademacher C, Olthoff G, Drescher D. Parameters affecting primary stability of orthodontic mini-implantsEinfluss der Insertionsparameter auf die Primärstabilität orthodontischer mini-Implantate. J Orofac Orthop/Fortschritte der Kieferorthopädie. 2006; 67: 162-74. https://doi.org/10.1007/s00056-006-0611-z

[10] Mattos CT, Ruellas ACdO, Elias CN. Is it possible to re-use mini-implants for orthodontic anchorage? Results of an in vitro study. Materials Research. 2010; 13: 521-5. https://doi.org/10.1590/S1516-14392010000400015

[11] Wilmes B, Panayotidis A, Drescher D. Fracture resistance of orthodontic mini-implants: a biomechanical in vitro study. The European Journal of Orthodontics. 2011; 33(4): 396-401. https://doi.org/10.1093/ejo/cjq151

[12] Park H-S, Jeong S-H, Kwon O-W. Factors affecting the clinical success of screw implants used as orthodontic anchorage. American Journal of Orthodontics and Dentofacial Orthopedics. 2006; 130(1): 18-25. https://doi.org/10.1016/j.ajodo.2004.11.032

[13] Merk BR, Stern SH, Cordes S, Lautenschlager EP. A fatigue life analysis of small fragment screws. Journal of orthopaedic trauma. 2001; 15(7): 494-9. https://doi.org/10.1097/00005131-200109000-00006

[14] Friberg B, Sennerby L, Gröndahl K, Bergström C, Bäck T, Lekholm U. On cutting torque measurements during implant placement: a 3‐year clinical prospective study. Clinical implant dentistry and related research. 1999; 1(2): 75-83. https://doi.org/10.1111/j.1708-8208.1999.tb00095.x

[15] Motoyoshi M, Yoshida T, Ono A, Shimizu N. Effect of cortical bone thickness and implant placement torque on stability of orthodontic mini-implants. International Journal of Oral & Maxillofacial Implants. 2007; 22(5). https://doi.org/10.1016/j.ijom.2008.09.006

Downloads

Published

2023-06-25

Issue

Section

Articles

How to Cite

Jamil, O. S. M., & Majeed, B. H. (2023). Comparison Of Fracture Torque And Level Of Fracture Of Two Orthodontic Mini-Screw ( AN IN VITRO STUDY). EURASIAN JOURNAL OF SCIENCE AND ENGINEERING, 9(2), 241-251. https://doi.org/10.23918/eajse.v9i2p19

Similar Articles

1-10 of 15

You may also start an advanced similarity search for this article.